RLVBMIM01 Mini Input Module
21 | 31/07/2009
Using the MIM01 with a Datalogger other than VBOX
The MIM01 can be configured to run in a Stand Alone CAN Bus mode using a RLVBCAB01 and RLVBCAB15 cable and Racelogic “Module Setup” software.
The cables RLVBCAB01 and RLVBCAB15 are supplied as standard if the MIM01 is ordered as a stand-alone module.
Configuring an MIM01 with Racelogic Module Setup Software
6. Connect the DATA1 socket on the MIM01 to a PC using the RLVBCAB01 cable.
7. Power up the MIM01 using a suitable 12v power source, this can be done with the
RLVBCAB15 cable connected to the DATA2 socket. Please observe correct polarity
(Red=12v, Black = Ground).
8. Run the Module Setup software. (supplied with a stand-alone module and also
available from the website, www.racelogic.co.uk
9. Click “Read Module Setup” – you should see a screen similar to that shown below.
The screenshot shows the settings for an MIM01. If you get a “No response”
message then check the MIM01 is correctly connected, the power supply is on and
that the correct COM Port is selected in the Module Setup software.
10. Make the changes required and then click the “Write Setup to Module” button.
Note: When any change is made using the Module Setup Software the POWER MUST
BE CYCLED for the change to take effect!