Seitenansicht 19
RLVBMIM01 Mini Input Module
20 | 31/07/2009
Setup Parameters Table
Parameter
Options
Comments
CAN Mode
Racelogic Polled mode
VBOX compatible mode.
In this mode no other parameter has any effect.
User Polled mode
Baud Rate must be set.
Extended Identifiers must be set.
Request Identifiers must be set.
Response Identifiers must be set.
Timed mode
Timer must be set.
Baud Rate must be set.
Extended Identifiers must be set.
Response Identifiers must be set.
Timer [ms]
(message interval in ms)
Minimum value is 10 (100Hz) below this value data may be erroneous.
If the Timer value is set to 0ms and Timed CAN Mode is on then Timer
value will be changed to 1ms.
Baud Rate [kbit/s]
1000 kbit/s
If a Baud Rate value other than those specified is entered it will be
changed to a default value of 500kbit/s.
500 kbit/s
250 kbit/s
125 kbit/s
Extended Identifiers
False/Standard (11 bit)
Request and Response Identifier range is 0 0x7FF (0 2047).
True/Extended (29 bit)
Request and Response Identifier range is 0 0x19FFFFFF (0
436207615).